英文版

中文版

热线电话

0755-23084885

当前位置: 首页 >>Products >>Oscilloscope
TDS3054C

名称:TDS3054C

产品介绍

TDS3054C Digital Fluorescent Oscilloscope
Bandwidth 500 MHz
Sampling rate 5.0 GS/s
Record length 10 k
Channel 4

TDS3000C 数字荧光示波器系列

TDS3000C Digital Fluorescent Oscilloscope Series

Brand: TEK

The performance you need, the price you can afford

Tektronix TDS3000C series oscilloscopes have a bandwidth of up to 500 MHz, providing economical performance in a compact battery powered design.

The TDS3000C series oscilloscope is now equipped with USB host port and PC connection software. It also provides familiar operation and simple navigation functions. You can learn and re learn how to use the oscilloscope in less time and complete the task at hand in more time.

Digital fluorescence oscilloscope

TDS3000C Series

 

characteristic

TDS3000C series electrical characteristics

TDS3012CTDS3014CTDS3032CTDS3034CTDS3052CTDS3054C
bandwidth 100 MHz 100 MHz 300 MHz 300 MHz 500 MHz 500 MHz
Calculated rise time (typical value) 3.5 ns 3.5 ns 1.2 ns 1.2 ns 0.7 ns 0.7 ns
Number of channels two four two four two four
External trigger input All models include
Sample rate per channel 1.25 GS/s 1.25 GS/s 2.5 GS/s 2.5 GS/s 5 GS/s 5 GS/s
Large record length 10 k sample points
Vertical resolution 9 bits
Vertical sensitivity, 1 M Ω 1 mV/div to 10 V/div
Vertical sensitivity, 50 Ω 1 mV/div to 1 V/div
Input coupling AC, DC, GND
Input impedance 1 M Ω when 13 pF or 50 Ω terminals are connected in parallel
DC gain accuracy 2%
Large input voltage (1 M Ω) 150 VRMS, peak value ≤ 400 V
Large input voltage (50 Ω) 5 VRMS, peak value ≤ 30 V
Positioning range 5 div
Bandwidth limit 20 MHz 20 MHz 20 MHz, 150 MHz 20 MHz, 150 MHz 20 MHz, 150 MHz 20 MHz, 150 MHz
Time base range 4 ns to 10 s 4 ns to 10 s 2 ns to 10 s 2 ns to 10 s 1 ns to 10 s 1 ns to 10 s
Time base precision At any 1 ms interval± 20 ppm
Input/output interface
Ethernet port RJ-45 connector, supporting 10Base-T LAN
USB port Front panel USB 2.0 host port, supporting USB flash memory
GPIB port Comprehensive call/answer mode, setting and measurement (optional for TDS3GV communication module)
RS-232-C port DB-9 male connector, comprehensive sending/receiving mode; Control all modes, setting and measuring baud rate 38400 (optional for TDS3GV communication module)
VGA video port DB-15 female connector, monitor output, direct display of information on a large monitor equipped with VGA (TDS3GV communication module optional)
External trigger input BNC connector, input impedance>1 M Ω, parallel current 17 pF; Large input voltage 150 VRMS
Acquisition mode
DPO Capture and display complex waveforms, random events, and subtle patterns in actual signal behavior. DPO can display, store and analyze the three-dimensional information of signals in real time, namely amplitude, time and amplitude distribution in each period.
Peak detection Capture high frequency and random burrs. Burrs as narrow as 1 ns can be captured.
WaveAlert® Monitor the input signal on all channels and warn the user when any waveform deviates from the captured normal waveform occurs.
sampling Data sampling only.
average value Average 2 to 512 (optional) captured waveform data
envelope The large/small value obtained on one or more acquisition signals.
Single Sequence Use the Single Sequence button to capture a single triggered capture sequence at a time.
Trigger system
Main triggering methods Automatic triggering (supports 40ms/lattice and slower scrolling mode), normal triggering, and single sequence triggering.
B trigger Triggered after a time or event.
Time trigger range 13.2 ns to 50 s
Event trigger range 1 to 9999999 events.
Trigger Type
edge Conventional level driven trigger. Positive and negative slopes on any channel. Coupling selection: DC, noise suppression, high-frequency suppression, low-frequency suppression.
video It can be triggered on all lines or single lines of NTSC, PAL, SECAM, odd/even or all fields.
Extend Video Can be triggered on broadcast and non broadcast (custom) standard specific lines and on analog high-definition TV formats (1080i, 1080p, 720p, 480p). The TDS3VID or TDS3SDI application module is required.
Pulse width (or burr) It can be triggered on a pulse width less than, greater than, equal to or not equal to the optional time limit range (39.6 ns - 50 s).
Underamplitude pulse It can be triggered on a pulse passing through a threshold, but cannot pass through the second threshold before passing through the threshold again.
Conversion rate It can be triggered at a pulse edge rate faster or slower than the set rate. It can be a rising edge, a falling edge, or both.
Code type Specify AND, OR, NAND, NOR when it is true or false at a specific time.
state Any logical state. The rising or falling edge of the clock can be triggered. You can use logic triggers on a combination of two inputs instead of four.
signal communication Provide the required isolation pulse trigger function for DS1/DS3 communication template test according to ANSI T1.102 standard. TDS3TMT application module is required.
alternate Use each active channel as the trigger source in order.
measurement system
cursor Range, time.
Automatic waveform measurement -Display the waveform measurement values of four arbitrary combinations. Or use the measurement snapshot function to display all measurement data. Measurement items include: cycle, frequency, width, - width, rise time, fall time, duty cycle, - duty cycle, overshoot, - overshoot, high, low, large, small, peak to peak, amplitude, average, average cycle, root mean square, root mean square of cycle, burst width, delay, phase, area * 1, cycle area * 1
Measurement statistics Average, small, large, standard deviation. The TDS3AAM application module is required.
threshold User defined automatic measurement threshold, which can be set by percentage or voltage.
Strobe You can use the screen or vertical cursor to isolate specific events that occur inside the collection for measurement.
Waveform mathematical operation
Algebraic operation Add, subtract, multiply, divide waveforms.
FFT Spectrum amplitude. Set the FFT vertical scale to linear RMS or dBV RMS, and set the FFT window to Rectangular, Hammering, Hanning, or Blackman Harris.
Advanced mathematical operation * 1

Integral, differential, and widely defined algebraic expressions, including analog waveforms, mathematical functions, scalars, two more user adjustable variables, and parameter measurement results.

Example: (Intg (Ch1 Mean (Ch1)) x 1.414 x VAR1).

Waveform processing
Automatic setting On the vertical, horizontal and trigger systems, one key can automatically set all channels, and the automatic setting function can be cancelled.
Offset correction The offset correction value between channels (± 10ns) can be input manually to obtain better timing measurement value and more accurate mathematical waveform.
Display characteristics
Display Type 6.5 inch (165.1 mm) LCD TFT color display.
Display resolution 640 pixels horizontal x 480 pixels vertical (VGA).
Interpolation Sin(x)/x
Waveform style Point, vector, variable afterglow, infinite afterglow.
Markings Full standard, grid, cross line, frame, NTSC, PAL, SECAM and oscilloscope (100% and 75% color bar vectors) require TDS3VID and TDS3SDI video application modules.
format YT, XY and gated XYZ (XY with Z-axis blank display is only available on 4-channel instruments).
Power Supply
AC power supply
supply voltage 100 VRMS- 240 VRMS± 10%。
Power frequency

45 Hz - 440 Hz at 100 V-120 V;

45 Hz - 66 Hz at 120 V - 240 V.

energy consumption Large 75 W.
Power supply Requires TDS3BATC rechargeable lithium battery
Typical working hours 3 hours
Environment and safety work Non work
temperature 0 º C to 50 º C -40 º C to 71 º C
humidity

Working and non working humidity: when the temperature is less than or equal to 30 ℃, the relative humidity is 95% higher;

Working and non working humidity: when the temperature is less than or equal to 50 ℃, the relative humidity is 45% higher.

height 3000m 15000m
electromagnetic compatibility Meet or exceed EN55011A radiation and conducted radiation standards; EN6100-3-2 AC power line harmonic radiation; EN6100-3-3 Voltage variation, fluctuation and flicker; FCC 47CFR, Part 15, Subpart B, Class A equipment; Australian EMC outline provisions.
security UL61010B-1, CSA1010.1, IEC61010-1, EN61010-1
Physical characteristics
instrument
External dimensions millimeter inch
width three hundred and seventy-five fourteen point eight
height one hundred and seventy-six six point nine
thickness one hundred and forty-nine five point nine
weight kg . pound
Net weight of instrument three point two seven
Install the battery four point five nine point eight
Instrument delivery
Packaging appearance dimension millimeter inch
width five hundred and two nineteen point eight
height three hundred and seventy-five fourteen point eight
thickness three hundred and sixty-nine fourteen point five
Rack mount (RM3000)
External dimensions millimeter inch
width four hundred and eighty-four nineteen
height one hundred and seventy-eight seven
thickness one hundred and fifty-two six

*1 TDS3AAM module is required.


【返回】

Copyright Shenzhen Zhongtai Instrument Co., Ltd. Tel.: 0755-23084885 Fax: 0755-23000265

Contact: Mr. Xiao 13760200976 Mr. Yang 13760220079

E-mail: zhongtaiyq@163.com Address: Room 1002, Guangfu Business Building, Baoyuan Road, Bao'an West Township, Shenzhen

粤ICP备17052778号