66312A

名称:66312A

产品介绍

characteristic

• Suitable for portable product testing

• Dynamic pulse measurement

• Precision low current measurement

• Low output noise

• High speed programming

• SCPI (Programmable Instrument Standard Command)

• HP-IB and RS-232 interfaces

Technical indicators:

Rated output

Voltage/current

0~20V/0~2A

Program control accuracy (25 ℃± 5 ℃

Voltage/current

0.05%

10mV/1 mV

Ripple and Noise
(20Hz-20 MHz output is not grounded or either end is grounded

Normal voltage mode
Voltage fast mode current

(rmp/p-p)
(rmp/p-p)
(rmp)

0.5 mV/3mV
NA
1 mA

DC measurement accuracy

Voltage

0.03%

3mV

Via HP-IB or panel table

Relative to 25 ℃± Actual output at 5 ℃

Low current range
-20 mA~ 20  mA


0.1%


two point five μ A

High current range
-20 mA~rated I
20 mA ~ - rated I


0.2%
0.2%


0.25 mA 0.85mA

load regulation

Voltage/current

2mV/0.5 mV

Power adjustment

Voltage/current

0.5mV/0.5 mV

Transient response time: (100 μ S (quick mode (50< μ s) As the load current changes in any step until it reaches 50% of the rated output current of the power supply, the output voltage returns to its previous level (within 0.1% of the rated voltage of the power supply)

Average programmed resolution

Voltage/current

5mV/0.5 mV

OVP accuracy

2.4%

240mV

Trap current*-

1A

*For the HP 66332A, when the programming current is>5 mA, the trap current tracks the programming current to within 2 mA: when the programming current is less than 5 mA. For the HP66312A, the trap current does not track the programmed current.

• Dynamic measurement: the accuracy of instantaneous voltage measurement is 0.03% 5mV. The accuracy of instantaneous current measurement is 0.6% 1mA (2mA for Agilent 66332A). DC, RMS, large, small, high and low level voltage and current measurements are calculated from instantaneous voltage and current readings. Up to 4096 data points can be obtained, and the sampling interval can be from 15.6 μ S changes to 31200s. Instantaneous data points can be read back from the cache. Dynamic measurement of current waveform with frequency component below 10kHz can be carried out in low or high current range. Above 10kHz, precise current measurement can only be carried out in high range.

• DC floating voltage: the output terminal can float greatly to the chassis ground&plusmn; 240Vdc (50V for 66,312A)

Remote detection: the voltage drop on each load lead can reach 2V For each voltage change on the negative output lead (positive output lead for 66312A) caused by the load current change, 2mV shall be added to the voltage load adjustment index

• Command processing time: for the power supply directly connected to GPIB (display failure), the average time required for the output voltage to start to change with the received digital data is 4ms

• Programming output response time: the rise and fall time of output voltage (10/90% and 90/10%) is less than 2ms (400 for 66332A in fast mode μ s)。 The time when the output voltage changes and stabilizes to within 1LSB of the final value (0.025% (rated voltage) is less than 6ms (2ms in fast mode)

• Measurement time: the average time for processing queries, calculating measurement parameters and returning data is 50ms. This includes the default 30ms and 20ms data processing overhead for acquisition.

• Input power (full load): 66312A: 160VA, 100W; 66332A:350VA,250W

• Compliance with specifications: listed in UL-3111-1; Via CSA22.2 No 1010-1 certification, complying with EN61010-1; Comply with EMC Guideline 89/336/EEC (ISM Group 1 Class B)